Basic Info.
Product Description
Features for TopPette- Lightweight, ergonomic, low force design
- Digital display clearly reads volume setting
- The pipettes cover volume range of 0.1μl to 10ml
- Easy to calibrate and maintain with tool supplied
- Design helps avoid repetitive strain injuries
- Calibrated in accordance with ISO8655. Each pipette supplied with individual test certificate
- The low part is available for autoclaving
Features for multi-channel TopPette- 8 and 12 channel pipettes are available for standard 96-well plate
- Dispensing head rotates for optimum pipetting convenience
- Individual piston and tip cone assemblies allow easy repair and maintenance
- Compound material tip cone design allows visual seal verification
- Can be used with universal style pipette tips
Specifications
Single-channel Adjustable Volume Pipettes |
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) |
% | μL | % | μL |
0.1-2.5μL | 0.05μL | 2.5μL | 2.50% | 0.0625 | 2.00% | 0.05 |
1.25μL | 3.00% | 0.0375 | 3.00% | 0.0375 |
0.25μL | 12.00% | 0.03 | 6.00% | 0.015 |
0.5-10μL | 0.1μL | 10μL | 1.00% | 0.1 | 0.80% | 0.08 |
5μL | 1.50% | 0.075 | 1.50% | 0.075 |
1μL | 2.50% | 0.025 | 1.50% | 0.015 |
2-20μL | 0.5μL | 20μL | 0.90% | 0.18 | 0.40% | 0.08 |
10μL | 1.20% | 0.12 | 1.00% | 0.1 |
2μL | 3.00% | 0.06 | 2.00% | 0.04 |
5-50μL | 0.5μL | 50μL | 0.60% | 0.3 | 0.30% | 0.15 |
25μL | 0.90% | 0.225 | 0.60% | 0.15 |
5μL | 2.00% | 0.1 | 2.00% | 0.1 |
10-100μL | 1μL | 100μL | 0.80% | 0.8 | 0.15% | 0.15 |
50μL | 1.00% | 0.5 | 0.40% | 0.2 |
10μL | 3.00% | 0.3 | 1.50% | 0.15 |
20-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 |
100μL | 0.80% | 0.8 | 0.30% | 0.3 |
20μL | 3.00% | 0.6 | 1.00% | 0.2 |
50-200μL | 1μL | 200μL | 0.60% | 1.2 | 0.15% | 0.3 |
100μL | 0.80% | 0.8 | 0.30% | 0.3 |
50μL | 1.00% | 0.5 | 0.40% | 0.2 |
100-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 |
500μL | 0.70% | 3.5 | 0.25% | 1.25 |
100μL | 2.00% | 2 | 0.70% | 0.7 |
200-1000μL | 5μL | 1000μL | 0.60% | 6 | 0.20% | 2 |
500μL | 0.70% | 3.5 | 0.25% | 1.25 |
200μL | 0.90% | 1.8 | 0.30% | 0.6 |
1000-5000μL | 50μL | 5000μL | 0.50% | 25 | 0.15% | 7.5 |
2500μL | 0.60% | 15 | 0.30% | 7.5 |
1000μL | 0.70% | 7 | 0.30% | 3 |
2-10mL | 0.1mL | 10mL | 0.60% | 60 | 0.20% | 20 |
5mL | 1.20% | 60 | 0.30% | 15 |
2mL | 3.00% | 60 | 0.60% | 12 |
8-channel Adjustable Volume Pipettes |
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) |
% | μL | % | μL |
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 |
5μL | 2.50% | 0.125 | 2.50% | 0.125 |
1μL | 4.00% | 0.04 | 4.00% | 0.04 |
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 |
25μL | 1.50% | 0.375 | 1.00% | 0.25 |
5μL | 3.00% | 0.15 | 2.00% | 0.1 |
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 |
150μL | 1.00% | 1.5 | 0.50% | 0.75 |
50μL | 1.50% | 0.75 | 0.80% | 0.4 |
12-channel Adjustable Volume Pipettes |
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) |
% | μL | % | μL |
0.5-10μL | 0.1μL | 10μL | 1.50% | 0.15 | 1.50% | 0.15 |
5μL | 2.50% | 0.125 | 2.50% | 0.125 |
1μL | 4.00% | 0.04 | 4.00% | 0.04 |
5-50μL | 0.5μL | 50μL | 1.00% | 0.5 | 0.50% | 0.25 |
25μL | 1.50% | 0.375 | 1.00% | 0.25 |
5μL | 3.00% | 0.15 | 2.00% | 0.1 |
50-300μL | 5μL | 300μL | 0.70% | 2.1 | 0.25% | 0.75 |
150μL | 1.00% | 1.5 | 0.50% | 0.75 |
50μL | 1.50% | 0.75 | 0.80% | 0.4 |
Fixed Volume Pipettes |
Volume Range | Increment | Test Volume | Maximum permissible systematic error (Inaccuracy) | Maximum permissible random error (Imprecision) |
% | μL | % | μL |
5μL | - | 5μL | 1.3% | 0.065 | 1.2% | 0.06 |
10μL | - | 10μL | 0.8% | 0.08 | 0.8% | 0.08 |
20μL | - | 20μL | 0.6% | 0.12 | 0.5% | 0.1 |
25μL | - | 25μL | 0.5% | 0.125 | 0.3% | 0.075 |
50μL | - | 50μL | 0.5% | 0.25 | 0.3% | 0.15 |
100μL | - | 100μL | 0.5% | 0.5 | 0.3% | 0.3 |
200μL | - | 200μL | 0.4% | 0.8 | 0.2% | 0.4 |
250μL | -- | 250μL | 0.4% | 1.0 | 0.2% | 0.5 |
500μL | - | 500μL | 0.3% | 1.5 | 0.2% | 1.0 |
1000μL | - | 1000μL | 0.3% | 3.0 | 0.2% | 2.0 |
2000μL | - | 2000μL | 0.3% | 6.0 | 0.15% | 3.0 |
5000μL | - | 5000μL | 0.3% | 15 | 0.15% | 7.5 |
Address:
No. 32 Fengtai North Road, Fengtai District, Beijing, China
Business Type:
Manufacturer/Factory
Business Range:
Health & Medicine, Industrial Equipment & Components
Management System Certification:
ISO 9001, ISO 9000, ISO 14001, ISO 14000, ISO 20000, OHSAS/ OHSMS 18001, IATF16949, HSE, ISO 14064, QC 080000, GMP, BSCI
Company Introduction:
Beijing Era Beili Centrifuge Co., Ltd. is a joint-stock company mainly engaged in the R&D, production and sales of centrifuges. Beijing Medical Centrifuge Factory is its predecessor. Its centrifuge series include low-speed centrifuges, high-speed centrifuges, and refrigerated centrifuge, etc. Which are divided into three grades: High, medium and low. They are widely used in central blood stations, blood banks, hospitals (for testing and radio immunity analysis), universities, research labs, as well as in the fields of agricultural science, biological engineering and environmental protection.
The company now has technicians and professionals with over 30 years of experiences in the design and R&D of centrifuges. The company adheres to the principle of inheritance, development and innovation. By taking reference of domestic and foreign centrifuge manufacturers′ product advantages, and introducing advanced production technology, the company has constantly improved its products in technical design, production process and has constantly launched high-quality products.
WE ARE ISO9001: 2000 INTERNATIONAL QUALIFICATION MANAGEMENT SYSTEM AUTHORIZED ENTERPRISE. AND WE HAVE GOT CE MARK.
Beijing Era Beili Centrifuge Co., Ltd. is looking forward to your participation and cooperation.